06.05.2013 X-COM Systems IQC5000A Series, Spectrum Capture and Playback System is the smallest, lightest, best-performing system available for the capture and playback of RF and microwave signals for mission-critical applications. Weighing less than 10 lb. and measuring only 12 x 3.5 x 10.5 in., the IQC5000A Series system can record and play back one or two independent channels of signal activity up to 160 MHz in bandwidth from HF through millimeter wavelengths.
The system's integrated data storage of up to 2 Tbytes and support for external 16 Tbyte datapacks gives users up to 6 hours of captured data at full bandwidth, and operation from 120/240 VAC or 12 VDC makes the IQC5000A Series equally suited for laboratory, production, or field applications.
Specifications
RF CAPTURE INTERFACE |
I&Q Inputs
|
- Logic level: LVDS
- Sample depth: 16-bit I&Q
- 2 Channels of I&Q: Accepts both inputs simultaneously
- Connector: Four 26-pin MDR
- Maximum data rate (Mbytes/s): 300 at each connector
- Spectrum analyzer compatibility:
Agilent: EXA, MXA and PXA Series
Rhode & Schwarz: FSV, FSVR, and FSW
Tektronix: RSA 5100/6100
- Minimum span (kHz): 10
- Span resolution (kHz): 10
- Maximum capture bandwidth (MHz): 160 (200 Msamples/s, 12 bits, I&Q) 110 (150 Msamples/s, 16 bits, I&Q)
|
PLAYBACK INTERFACE |
Mirror Port
|
Real-time access to digital input port data; one pair of inputs
- Logic level: LVDS
- Data rate (Mbytes/s): 300 at each connector
- Connector: Two 26-pin MDR
|
Analog I&Q Outputs
|
2 channels operating simultaneously, baseband, analog
- 1-dB bandwidth (MHz): 110 centered at 0 Hz
- Power level (dBm): 0 (fixed)
- Amplitude flatness across 110 MHz bandwidth (dB): +/-2
- VSWR: ≤ 1.8:1
- Impedance (ohms): 50
- Connector: SMA female
|
RF Outputs
|
Channel 1
- Center frequency (MHz): 2400
- Information bandwidth (MHz): 110
- Power level (dBm): 0 to -60 in 1-dB steps
- LO leakage (dBm): -60
- SFDR (dB): TBD
- Phase noise (dBc/Hz): TBD
- VSWR: ≤ 1.8:1
- Impedance (ohms): 50
- Connector: SMA female
|
GENERAL SPECIFICATIONS |
GPS
|
- Protocol: ASCII, 8-bit data, one start and one stop bit, no parity
- Speed (Kb/s): 115.2
- Active control lines: RTS, CTS
- Connector: 9-pin D female
|
IRIG-B
|
- Accuracy: IRIG-B122
- Voltage levels: Amplitude modulated, 3 Vpp, sine wave carrier
- Read rate: 1/s
- Maximum number of time tags: 100,000
- Connector: SMA female
|
Markers
|
2 Inputs
- Voltage levels (VDC): 0 to 3.3 threshold, 5 maximum
- Impedance (ohms): 50
- Connector: SMA female
- Maximum allowed per capture: 100,000
- Marker content: Date, time of day, latitude, longitude, altitude, GS, sample number
- Latency (μs): <1 from marker valid at connector to insertion in capture file
- Minimum time between markers (ms): <1
|
Trigger Functions
|
2 Inputs
- Voltage levels (VDC): 0 to 3.3 threshold, 5 maximum
- Impedance (ohms): 50
- Connector: SMA female
- Latency from trigger valid to first sample write (μs): <1
- Re-arm time (ms): <1
- Pre-capture memory (μs): 10
- START/STOP CAPTURE
- Capture Types: Timed, manual
- Port configurations: Port 1, port 2, ports 1 and 2, ports 1 or 2
- Logic (user-specified): Leading edge valid, trailing edge valid (after start pulse or same pulse)
- START/STOP PLAYBACK
- Playback modes: Timed, manual, looped until trigger, play between markers
- Port configurations: Port 1, port 2, ports 1 and 2, ports 1 or 2
- Logic (user-specified): Leading edge valid, trailing edge valid (after start pulse or same pulse)
|
Reference Clocks
|
- INTERNAL
- Frequency (MHz, +/-ppm): 10, +/-10
- EXTERNAL (Provided by external input port if active. Otherwise internal clock signal is used)
- Required level (dBm): >0 into 50 ohms
- Frequency (MHz, +/-ppm): 10, +/-10
- Connector: SMA female
|
Markers
|
- Maximum allowed per capture: 100,000
- Marker content: Date, time of day, latitude, longitude, altitude, GS, sample number
- Latency (μs): <1 from marker valid at connector to insertion in capture file
- Minimum time between markers (ms): <1
|
Wavrform Storage
|
- Internal Solid State: NAND flash
- Internal Size (GBytes per blade): 500, maximum 4 blades
- External Rotating magnetic: RAID 0
- External Size (Tbytes): 8, 16
|
Instrument Control
|
- X-COM Control software: Graphical user interface, full control of capture, playback, file manipulation, offload and upload.
- Operating environment: SIngle-core desktop or laptop, Windows XP or 7, 50 Mbytes RAM, 100 Mbytes free disk space, mouse
- Remote API: RJ-45 connection to LAN switch
- Front Panel: Limited capture and playback control (start, stop, capture) via membrane switches and 2-line LCD
|
PCIe (Data Offload)
|
- Specification: 1.0
- Lanes: 4
|
Environmental
|
MIL-PRF-28880F Class 3 except where noted by*
- Temperature: 0° to +50° C operating , -20° C* to +71° C storage. 95% relative humidity (non-condensing)
- Vibration: Sinusoidal: 5 to 55 Hz, 0.33 mm amplitude. Random with solid-state drives installed: in conformance with MIL-PRF-28880F Class 3
- Shock (non-operating): 30g
|
Power
|
- AC: 100 to 240 +/-10%, 50 to 60 Hz +/-5%, at 1.1 to 2.5 A (72 W)
- DC: 12 VDC, 6 A maximum (72 W)
|
Dimensions
(W x H x D)
|
12" x 3.5" x 10.5"
305 x 89 x 266 mm
|
Weight (lb., kg)
|
8.5Z
3.85
|
Product Conformity
|
- Electromagnetic conformance: EMC Directive 2004/108/EC EN 61326-1 and EN 61326-2-1 electrical equipment for measurement, control, and laboratory use
- Electical safety conformance: Safety Directive 2006/95/EC EN 61010-1 safety requirements for electrical equipment for measurement, control, and laboratory use - General Requirements
|
| |