Built with color touchscreen and DSP technology, Vitrek's compact, rugged V7X Hipot Series deliver 5 KV AC/DC output, leakage to 100 nA, IR to 450GΩ, and 30 A ground bond. Unbeatable speed, accuracy, and safety — meet tough UL, CSA, TUV Hipot specifications.
- 4.3" Color Touch Display - Easy To Use Intuitive User Interface
- 5 Function Combinations to Choose From - AC/DC Hipot, Insulation Resistance, Ground Bond, Low Resistance
- Test Memory Stores up to 999 Steps and 60 Test Sequences
- Made in the USA - Designed & Built in San Diego CA
- Compact, Lightweight, Rugged
- 100 nano Amp Leakage Current Resolution
- Low Cost of Ownership - 2 Year Calibration Interval, Fan Free Design
- USB 2.0, Serial/RS232, Digital I/O Interfaces are Standard
- Continuously Variable Insulation Resistance 20-5,000V
- Multi Mode IR with Steady or Rising Pass Mode
- Internal Self Test Fully Exercises Output and Verifies Current Accuracy
- Pre-Programmed Daily Verification Test With Optional PVD Test Load
- 150µS Safety Shutdown
- Ramped Discharge Capability
- Selectable ARC Detection
- Meets UL, CSA, IEC Safety Tester Requirements
- CE Safety Mark Certified to EN61010
- 2 Year Parts & Labor Warranty
AC Hipot
Output Voltage 10 to 5000V 50 or 60 Hz
Accuracy: 1.4% of setting +0.1% Full Scale, No load to full load
Resolution: 1V at all levels
Max load current: 20mArms
Leakage Current Min/Max Limits during dwell of none, or up to 20mArms
Accuracy: 1.5% of reading +5uA
Resolution: 1uA
DC Hipot
Output Voltage 20 to 5000V test voltage
Accuracy: 1.4% of setting+0.1% Full Scale, No load to full load
Resolution: 1V at all levels
Max load current: 10mA
Leakage Current Accuracy: 1.5%+1uA
Resolution: 0.1uA
IR - Insulation Resistance
Test Voltage 20 to 5000VDC
Accuracy: 5%+5V No load to full load
Resolution: 1V at all levels
Max Charge Current: 5mA automatic
Max Capacitive Load: 2uF
Resistance Max IR: 450Gigohm (90MΩ per volt)
Min IR: 150KΩ
Accuracy: 2%(rdg <5% of max IR), 5%(< 15% of max IR), 10%(< 30% of max IR), 20%(above 30% of max IR)
Max Resolution: 0.1% of value
Min/Max Limits: Defined for each step, max may be set to none
Test Completion Stop on Time: Determination on final reading
Stop on Pass: Test terminates with PASS for any reading within limits
Stop on Fail: Test terminates with FAIL for any reading outside limits
Stop on Steady: Test terminates with PASS for any reading within limits which is Steady or Rising
Low Resistance
Resistance Range: 0ohm to 60Kohm
Accuracy: 1.4 %+0.02Ω (<10Ω), 3%+1ohm (<1KΩ), 10 % above 1KΩ
Resolution: Down to 0.001Ω
Min/Max Limits: Defined for each step, each may be set to none
Test Method 2 terminal measurement , 10.5mA max, 4.15V max
Resistance Offset Test leads/fixture measurement offset may be universally applied
Ground Bond
Test Current 1 to 30Arms (42A pk), 50/60Hz
Accuracy: 2.5%+10mA
Resolution: settable to 0.01A at all levels
Compliance: > 4.5Vrms (6V pk) for all currents
Test Method 4 terminal measurement
Resistance Max Resistance: Up to compliance V limit at defined test current (4.5ohms max)
Min/Max Limits: Defined for each step, min may be set to none
Accuracy: 2.5%+3mΩ (<2A), 2mΩ (<6.5A), 1mΩ (otherwise)
Resolution: 0.1mΩ (>6.5A), 1mΩ (otherwise)
Resistance Offset Test leads/fixture measurement offset may be universally applied
Test Timing
Ramp Time For AC/DC Hipot: 0 to 99.9sec (0.1sec resolution, 0.05sec accuracy)
Test/Dwell Time 0.1 to 9999sec or user end (0.1sec resolution, 0.15sec accuracy)
Ramp Down May be set to 0sec or same as Ramp time, automatically skipped if no failure and next step is same
AC/DC or IR test type
Shutdown Breakdown: within 150us
HV Safety: within 1ms
User Stop or Interlock opened: within 2ms
Resistance/Current Limit: within 100ms
Test Functions
|
V70
|
V71
|
V73
|
V74
|
V79
|
AC Hipot
|
●
|
●
|
●
|
●
|
|
DC Hipot
|
|
●
|
●
|
●
|
|
IR
|
|
|
●
|
●
|
|
Ground Bond
|
|
|
|
●
|
●
|
Low Resistance
|
●
|
●
|
●
|
●
|
●
|
Breakdown For Hipot tests, automatically checks for sudden uncontrolled increases of load current throughout test,
no min/max leakage required
Arc Detect For Hipot tests, settable to none or adjustable level between 1 and 30mApk, 5MHz bandwidth
Pause Step A timed pause of defined length between 0.1s and 999.9s.
Hold Step A user continued hold step with a 2 line message to be displayed to the user while the step is
executing.
Switch Step Provides control of up to 4 Vitrek 964 switch units, each SWITCH step allows complete control over
the states of all switches
Test Memory Up to 999 total test steps may be defined in up to 60 different sequences