11.10.2012
Features and Benefits
- 10/100BaseT(X) auto-negotiation and auto-MDI/MDI-X
- Link Fault Pass-Through (LFP)
- Power failure alarm by relay output
- Redundant dual DC power inputs
- M12 anti-vibration connector
- -40 to 85°C operating temperature range
Introduction
The PTC-101-M12 EN 50121-4 Ethernet-to-fiber media converters convert from 10/100BaseT(X) to 100BaseFX. The models are available with SC/ST connectors in fiber and M12 connector in Ethernet to provide a reliable communication. The PTC-101-M12 converters eliminate the need for additional wiring, and support IEEE 802.3 and IEEE 802.3u/x protocols with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for your industrial Ethernet networks. The PTC-101-M12 is compliant with EN 50121-4 and is well suited for high-vibration wayside locations of railway applications.
• Technology |
Standards |
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X), 100BaseFX |
• Interface |
RJ45 Ports |
10/100BaseT(X) |
Fiber Ports |
100BaseFX (SC/ST connectors) |
LED Indicators |
PWR1, PWR2, Fiber Link (fiber port), 10/100M (TP port) |
Alarm Contact |
One relay output with current carrying capacity of 1 A @ 24 VDC |
DIP Switches |
|
• Optical Fiber |
|
• Physical Characteristics |
Housing |
Metal |
Dimensions |
124 x 145 x 67 mm (4.88 x 5.7 x 2.63 in) |
Weight |
617 g |
Installation |
WK-51 (wall mount) |
• Environmental Limits |
Operating Temperature |
-40 to 85°C (-40 to 185°F) |
Storage Temperature |
-40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity |
5 to 95% (non-condensing) |
Conformal Coating |
N/A |
• Power Requirements |
Input Voltage |
20 to 72 VDC |
Connection |
Removable terminal block |
Overload Current Protection |
1.6 A (protects against two signals shorted together) |
Reverse Polarity Protection |
Protects against V+/V- reversal |
• Standards and Certifications |
EMC |
CE, FCC |
EMI |
EN 55022 Class A |
EMS |
EN 61000-4-2 (ESD) Level 4,
EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 4,
EN 61000-4-5 (Surge) Level 4,
EN 61000-4-6 (CS) Level 3,
EN 61000-4-8 (PFMF) Level 5,
EN 61000-4-9 |
Rail Traffic |
EN 50155, EN 50121-4 |
Vibration |
EN 50125-3 |
Green Product |
RoHS, CRoHS, WEEE |
• Warranty |
Warranty Period |
5 years |
| |