The Traco Power TEP 75-200 Series of high power DC/DC converter modules are ultra-compact and high power, with output power from 75W up to 240W. Packaged in a rugged, sealed metal case with aluminum baseplate and optional heat sink that allows full load operation up to 60°C with convection cooling. Featuring 2:1 or 4:1 wide input voltage ranges, high-efficiency up to 93%, under-voltage lockout, reverse input voltage protection, input protection filter and a 3-year product warranty.
Additional features include EMI Filter to meet EN 55022 Class A, detailed application notes, and additional filtering component recommendations to meet EN 55022 Class B conducted. These modules can be mounted to a printed circuit board, with or without a heat sink, chassis mounted screw terminal connections with filter, and DIN-Rail mount. Typical applications are in telecom/datacom, industry control and transportation/railway systems for on board power distribution.
Input Specifications for TEP 75WI Series, 75 Watt
Input current at no load 24 Vin; 5 – 15 VDC models: 185 mA typ.
24 Vin; 24 – 48 VDC models: 85 mA typ.
48 Vin; 5 – 15 VDC models: 90 mA typ.
48 Vin; 24 – 48 VDC models: 50 mA typ.
Input current at full load 24 Vin models: 3600 mA typ. (see Note 1)
48 Vin models: 1800 mA typ.
Start-up voltage / under voltage lockout 24 Vin models: 8.5 VDC / 7.5 VDC (or lower)
48 Vin models: 17.5 VDC / 16 VDC (or lower)
Surge voltage (100 msec. max.) 24 Vin models: 50 V max.
48 Vin models: 100 V max.
Conducted noise – with option –CMF EN 55022 class A, FCC part 15, level A
– for PCB mount version See application note for to meet
EN 55022 class A or B
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
Fast transient / Surge EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV perf. criteria A
With external input capacitor e.g. Nippon
chemi-con KY 200 µF, 100 V, ESR 48 mOhm
or with chassis mount option –CFM
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Reverse voltage protection parallel diode (external input fuse required)
Recommended input fuse (slow blow) 24 Vin models: 10 A
48 Vin models: 5 A
Output Specifications
Voltage set accuracy ±1 %
Output voltage adjustment +10 % / –20 % by external resistor
see application note:
Regulation – Input variation Vin min. to Vin max. 0.2 % max.
– Load variation (0 – 100 %) 5 – 15 VDC models: 0.3 % max.
24 – 48 VDC models: 0.3 % max.
Temperature coefficient ±0.02 %/K
Minimum load not required
Remote sense 10 % max. of Vout nom.
(trim up value to subtract)
Ripple and noise (20 MHz Bandwidth) 5 VDC models: 75 mVpk-pk max.
12 & 15 VDC models: 100 mVpk-pk max.
24 & 28 VDC models: 200 mVpk-pk max.
48 VDC models: 300 mVpk-pk max.
Start up time (nominal Vin and constant resistive load) 25 ms typ. (at power On or remote On)
Transient response (25 % load step change) 200 µs typ.
Output current limitation at 110 – 140 % of Iout max.
Over voltage protection at 115 – 130 % of Vout nom.
Short circuit protection indefinite, automatic recovery.
DC/DC Converters
TEP 75WI Series 75 Watt
Note 1:
For 24 VDC input voltage models an input capacitor 4.7µF/50V X7R MLCC or 68µF/100V, 110mOhm Nippon chemi-con KY series is
recommended for a reliable supply of the pulse current. Capacitor is already include with chassis mount option –CM and –CFM